SQUID MIDI Implementation Guide This document describes the MIDI messages transmitted and received by the SQUID. You can edit the SQUID MIDI settings in the [GLOBAL] setting of this unit. For the MIDI settings of this unit, please refer to the Operating Instructions. MIDI Messages System Real Time Messages Status 0111 1000 0111 1010 0111 1011 0111 1100 Description MIDI Timing Clock Start Continue Stop Received Channel Messages SQUID records the received MIDI messages in a sequence. Status Description 1st data byte 2nd data byte 3rd data byte 1000 nnnn 0kkk kkkk 0vvv vvvv Note Off. Velocity is ignored. 1001 nnnn 0kkk kkkk 0vvv vvvv Note On. Note Off if 0vvv vvvv=0. Transmitted Channel Messages Status 1st data byte 2nd data byte 3rd data byte 1001 nnnn 0kkk kkkk 0vvv vvvv 1011 nnnn 0vvv vvvv 0vvv vvvv 1100 nnnn 0vvv vvvv 0000 0000 Description Note On. Note Off if 0vvv vvvv=0. Control Change. See "Transmitted Controller Messages". Program Change. Transmitted Controller Messages Status Description 1st data byte 2nd data byte 3rd data byte 1011 nnnn 0000 0000 0vvv vvvv Bank Select(MSB). 1011 nnnn 0010 0000 0vvv vvvv Bank Select(LSB). 1011 nnnn 0111 1000 0000 0000 All Sound Off. * In addition, SQUID has a mode to transmit Control Change MIDI message called CC mode. You can control the parameters of external equipment from the unit by assigning up to 5 MIDI controller numbers to each track and sequencing (step recording) the MIDI control values into each step. For details of CC mode, please refer to the Operating Instructions. Where: 0kkk kkkk nnnn 0vvv vvvv Note Number 0-127. Channel Number 0 to 15 ( MIDI Channel 1 to 16 ). * Ignored if MIDI channel set to ALL. Value 2019 Pioneer DJ Corporation. All rights reserved.